Bugs fixed:
In the MySqlDataReader
class the
GetSByte
function returned a
byte
value instead of an
sbyte
value.
(Bug#46620)
When trying to create stored procedures from a SQL script, a
MySqlException
was thrown when attempting to
redefine the DELIMITER
:
MySql.Data.MySqlClient.MySqlException was unhandled Message="You have an error in your SQL syntax; check the manual that corresponds to your MySQL server version for the right syntax to use near 'DELIMITER' at line 1" Source="MySql.Data" ErrorCode=-2147467259 Number=1064 StackTrace: à MySql.Data.MySqlClient.MySqlStream.ReadPacket() à MySql.Data.MySqlClient.NativeDriver.ReadResult(UInt64& affectedRows, Int64& lastInsertId) à MySql.Data.MySqlClient.MySqlDataReader.GetResultSet() à MySql.Data.MySqlClient.MySqlDataReader.NextResult() à MySql.Data.MySqlClient.MySqlCommand.ExecuteReader(CommandBehavior behavior) à MySql.Data.MySqlClient.MySqlCommand.ExecuteReader() à MySql.Data.MySqlClient.MySqlCommand.ExecuteNonQuery() à MySql.Data.MySqlClient.MySqlScript.Execute()
Note: The MySqlScript
class has been fixed to
support the delimiter statement as it is found in SQL scripts.
(Bug#46429)
The MySQL Connector/NET Profile Provider,
MySql.Web.Profile.MySQLProfileProvider
,
generated an error when running on Mono. When an attempt was
made to save a string in Profile.Name
the
string was not saved to the
my_aspnet_Profiles
table. If an attempt was
made to force the save with Profile.Save()
the following error was generated:
Server Error in '/mono' Application -------------------------------------------------------------------------------- The requested feature is not implemented. Description: HTTP 500. Error processing request. Stack Trace: System.NotImplementedException: The requested feature is not implemented. at MySql.Data.MySqlClient.MySqlConnection.EnlistTransaction (System.Transactions.Transaction transaction) [0x00000] at MySql.Data.MySqlClient.MySqlConnection.Open () [0x00000] at MySql.Web.Profile.MySQLProfileProvider.SetPropertyValues (System.Configuration.SettingsContext context, System.Configuration.SettingsPropertyValueCollection collection) [0x00000] -------------------------------------------------------------------------------- Version information: Mono Version: 2.0.50727.1433; ASP.NET Version: 2.0.50727.1433
When using MySQL Connector/NET 6.0.4 and a MySQL Server 4.1 an exception was generated when trying to execute:
connection.GetSchema("Columns", ...);
The exception generated was:
'connection.GetSchema("Columns")' threw an exception of type 'System.ArgumentException'System.Data.DataTable {System.ArgumentException} base{"Input string was not in a correct format.Couldn't store <'Select'> in NUMERIC_PRECISION Column. Expected type is UInt64."}System.Exception {System.ArgumentException}
The MySQL Connector/NET method
StoredProcedure.GetParameters(string)
ignored
the programmer's setting of the
UseProcedureBodies
option. This broke any
application for which the application's parameter names did not
match the parameter names in the Stored Procedure, resulting in
an ArgumentException
with the message
“Parameter 'foo' not found in the collection.” and
the following stack trace:
MySql.Data.dll!MySql.Data.MySqlClient.MySqlParameterCollection.GetParameterFlexible(stri ng parameterName = "pStart", bool throwOnNotFound = true) Line 459C# MySql.Data.dll!MySql.Data.MySqlClient.StoredProcedure.Resolve() Line 157 + 0x25 bytesC# MySql.Data.dll!MySql.Data.MySqlClient.MySqlCommand.ExecuteReader(System.Data.CommandBeha vior behavior = SequentialAccess) Line 405 + 0xb bytesC# MySql.Data.dll!MySql.Data.MySqlClient.MySqlCommand.ExecuteDbDataReader(System.Data.Comma ndBehavior behavior = SequentialAccess) Line 884 + 0xb bytesC# System.Data.dll!System.Data.Common.DbCommand.System.Data.IDbCommand.ExecuteReader(System .Data.CommandBehavior behavior) + 0xb bytes System.Data.dll!System.Data.Common.DbDataAdapter.FillInternal(System.Data.DataSet dataset = {System.Data.DataSet}, System.Data.DataTable[] datatables = null, int startRecord = 0, int maxRecords = 0, string srcTable = "Table", System.Data.IDbCommand command = {MySql.Data.MySqlClient.MySqlCommand}, System.Data.CommandBehavior behavior) + 0x83 bytes System.Data.dll!System.Data.Common.DbDataAdapter.Fill(System.Data.DataSet dataSet, int startRecord, int maxRecords, string srcTable, System.Data.IDbCommand command, System.Data.CommandBehavior behavior) + 0x120 bytes System.Data.dll!System.Data.Common.DbDataAdapter.Fill(System.Data.DataSet dataSet) + 0x5f bytes
Conversion of MySQL TINYINT(1)
to
boolean
failed.
(Bug#46205, Bug#46359, Bug#41953)
If the application slept for longer than the specified
net_write_timeout
, and then resumed
Read
operations on a connection, then the
application failed silently.
(Bug#45978)
When reading data, such as with a
MySqlDataAdapter
on a
MySqlConnection
, MySQL Connector/NET could potentially
enter an infinite loop in
CompressedStream.ReadNextpacket()
if
compression was enabled.
(Bug#43678)
An error occurred when building MySQL Connector/NET from source code checked out from the public SVN repository. This happened on Linux using Mono and Nant. The Mono JIT compiler version was 1.2.6.0. The Nant version was 0.85.
When an attempt was made to build (for example) the MySQL Connector/NET 5.2 branch using the command:
$ nant -buildfile:Client.build
The following error occurred:
BUILD FAILED Error loading buildfile. Encoding name 'Windows-1252' not supported. Parameter name: name
MySQL Connector/NET CHM documentation stated that MySQL Server 3.23 was supported. (Bug#42110)
Using a DataAdapter
with a linked
MySqlCommandBuilder
the following exception
was thrown when trying to call da.Update(DataRow[]
rows)
:
Connection must be valid and open
User Comments
Add your own comment.