# NetWorker
# 7.2.2.Build.422
# LEGATO Software, a division of EMC.
#
# SEAGATE ASC/ASCQ Error Codes
#
0x29, 0x80, drive failed power-on test or diagnostic
0x30, 0x80, Firmware tape update failed
0x30, 0x84, Entity header wrong length
0x30, 0x85, Reserve byte not in entity header
0x30, 0x86, Bad algorithm byte in entity header
0x30, 0x87, Invalid entity record length field
0x30, 0x88, Invalid entity record count field
0x30, 0xc3, Compressed data format corruption
0x30, 0xc4, Block Access Table corruption during reading
0x3b, 0xbf, Tape position error with head clog
0x40, 0x81, Diagnostic failed FLASH memory checksum test
0x40, 0x82, Diagnostic failed RAM test
0x40, 0x83, Diagnostic failed memory controller test
0x40, 0x84, Diagnostic failed counter/timer test
0x40, 0x85, Diagnostic failed SCSI LSI test
0x40, 0x86, Diagnostic failed ECC processor test
0x40, 0x87, Diagnostic failed tape formatter LSI test
0x40, 0x88, Diagnostic failed compression LSI test
0x40, 0x89, Diagnostic failed EEPROM test
0x40, 0xa0, Diagnostic initialization failed
0x40, 0xa1, Diagnostic SBIST failed
0x40, 0xa2, Diagnostic BBIST failed
0x40, 0xa3, Diagnostic DBIST failed
0x40, 0xa4, Diagnostic DMA setup failed
0x40, 0xa5, Diagnostic host interface RAM failed
0x40, 0xa6, Diagnostic AIC RAM failed
0x40, 0xa7, Diagnostic DMA write interrupt failed
0x40, 0xa8, Diagnostic DMA write FIFO overrun
0x40, 0xa9, Diagnostic DMA write offset error
0x40, 0xaa, Diagnostic DMA write host interface parity error
0x40, 0xab, Diagnostic DMA write RD parity error
0x40, 0xac, Diagnostic DMA write micro port access error
0x40, 0xad, Diagnostic DMA write counter error
0x40, 0xae, Diagnostic DMA write data compare error
0x40, 0xaf, Diagnostic DMA read interrupt failed
0x40, 0xb0, Diagnostic DMA read FIFO overrun
0x40, 0xb1, Diagnostic DMA read offset error
0x40, 0xb2, Diagnostic DMA read HI parity error
0x40, 0xb3, Diagnostic DMA read RD parity error
0x40, 0xb4, Diagnostic DMA read micro port access error
0x40, 0xb5, Diagnostic DMA read counter error
0x40, 0xb6, Diagnostic DMA read data compare error
0x40, 0xb7, Invalid SANCHO revision
0x40, 0xb8, Diagnostic task status unknown
0x40, 0xb9, Diagnostic, cable problems
0x40, 0xba, Diagnostic, excessive reset conditions
0x40, 0xbb, Diagnostic, AIC in reset mode
0x40, 0xbc, Diagnostic, micro port access not cleared
0x40, 0xbd, Diagnostic; task timeout
0x40, 0xbe, Diagnostic, Flash test failure
0x40, 0xbf, Diagnostic, SDRAM test failure
0x40, 0xc0, Diagnostic, EEPROM test failure
0x40, 0xc1, Diagnostic, Cronus SRAM test failure
0x40, 0xc2, Diagnostic, Kukai DRAM test failure
0x40, 0xc3, Diagnostic, Cronus SRAM test failure
0x40, 0xc4, Diagnostic, Cronus RW passthrough failure
0x40, 0xc5, Diagnostic, Cronus RW compression failure
0x44, 0xad, Capstan servo error
0x44, 0xae, Tape cylinder error
0x44, 0xaf, Tape reel error
0x44, 0xb4, Internal tape process error
0x44, 0xb7, Internal error - invalid tape status
0x44, 0xb9, Internal error - drive error
0x44, 0xba, Internal error - SDA search failed
0x44, 0xbb, Internal error - tape erase failed
0x44, 0xbc, Internal error - invalid append AFC
0x44, 0xbd, Internal error - missed R3CP
0x44, 0xbe, Hardware adjustment error
0x44, 0xc0, Loader error - initialization failed at first reference point
0x44, 0xc1, Loader error - initialization failure
0x44, 0xc2, Loader error - magazine ejection failed
0x44, 0xc3, Loader error - elevator cannot move upward
0x44, 0xc4, Loader error - elevator cannot move downward
0x44, 0xc5, Loader error - cartridge cannot be moved into drive
0x44, 0xc6, Loader error - cartridge cannot be inserted into magazine slot
0x44, 0xc7, Loader error - cartridge cannot be extracted from magazine slot
0x44, 0xc8, Loader error - cartridge cannot be moved from drive
0x44, 0xc9, Loader error - magazine cannot be moved into loader
0x44, 0xca, Loader error - magazine platform cannot rotate
0x44, 0xcb, Loader error - unable to lock door
0x44, 0xcc, Loader error - internal error A
0x44, 0xcd, Loader error - internal error B
0x44, 0xd0, AIC internal DMA FIFO over/under run
0x44, 0xd1, AIC internal DMA offset error
0x44, 0xd2, AIC internal DMA parity error
0x44, 0xd3, AIC internal read parity error
0x44, 0xd4, Microprocessor Cache Failure
0x44, 0xd5, EEPROM failure
0x5d, 0xff, Tape Alert Flag tested
0x80, 0x00, cleaning request - (SEAGATE unique)
0x80, 0x01, motor monitor timeout
0x81, 0xa0, Media failed calibration
0x82, 0x80, humidity detected
0x83, 0x01, MIC header error
0x83, 0x02, No MIC detected
0x83, 0x03, MIC checksum error
0x83, 0x04, MIC out of memory
0x83, 0x05, No data body detected in the MIC
0x83, 0x06, MIC read error
0x83, 0x07, No cassette detected
0x83, 0x08, MIC is not formatted
0x83, 0x09, MIC write fault
0x83, 0x0a, Requested address is write-protected on the MIC
0x83, 0x0b, MIC is broken
0x83, 0x0c, MIC format type unidentified
0x83, 0x0d, MIC capacity field indicates illegal value (Acceptable values are 2KB, 4KB, 8KB, 16KB, 32KB and 64KB.)
0x83, 0x80, Position information from tape is different from position information on MIC. Tape has been rewound to PBOT.
0x83, 0x80, Partition count exceeded
0x83, 0x81, AIT bit condition mismatched
0x83, 0x82, System log should be in MIC but cannot write
0x83, 0x83, MIC exists but is not used
0x83, 0x84, System log should be in MIC but MIC is new
0x83, 0x85, No system-log area on tape, but MIC is formatted
0x83, 0x86, System log is on tape but MIC has formatted
0x83, 0x87, System log should be in MIC but cannot read
0x83, 0x88, AIT native-mode cartridge is in DDS-emulating drive (force to read only)
0x83, 0x89, User volume note-size mismatch
0x83, 0x8a, User partition note-size mismatch
0x83, 0x8b, No corresponding partition found for the user partition note
0x83, 0x8c, PRTH (Prevent threading) mode
0x83, 0x8d, No password for this MIC
0x83, 0x8e, Password mismatching
0x83, 0x90, Buffer memory full
0x83, 0x91, Partition has optional device area
0x83, 0x93, User volume note and user partition note are write protected
0x83, 0x94, Partition is write protected
0x83, 0x95, Partition is read protected
0x83, 0x96, The partition is collapsed.
0x83, 0x97, Current partition is not the last partition
0x83, 0x98, Cannot append the new partition because of insufficient capacity
0x83, 0x99, Cannot delete partition because the partition number is not appropriate