# NetWorker
# 7.2.2.Build.422
# LEGATO Software, a division of EMC.
#
# TANDBERG ASC/ASCQ Error Codes
#
0x04, 0x82, I/O Port is extended
0x04, 0x83, Front door is open
0x04, 0x85, Front door is open
0x04, 0x86, Source Magazine not installed
0x04, 0x86, Destination Magazine not installed
0x04, 0x8d, Logical unit not ready - front panel mode
0x04, 0x8e, Logical unit not ready - sequential mode
0x24, 0x80, Invalid Element Address
0x28, 0x8c, Not ready to ready transition - magazine door closed
0x28, 0x8d, Not ready to ready transition - exited menu mode
0x28, 0x8e, Not ready to ready transition - exited sequential mode
0x28, 0x8f, Not ready to ready transition - magazine door opened
0x3b, 0x80, Illegal move command
0x3b, 0x83, Tape is not ejected from drive
0x3b, 0x84, Destination Drive not installed
0x3b, 0x87, Cannot move - element in error
0x3b, 0x90, Tape is not ejected from drive
0x3b, 0x91, Cannot move - element not installed
0x3f, 0x80, Flash prom programming error
0x3f, 0x82, Flash update download error
0x3f, 0x84, Flash update program error
0x3f, 0x86, Flash update CRC error
0x3f, 0x88, Cannot execute flash update
0x40, 0x80, Diagnostic failure
0x80, 0x00, First Destination Element empty
0x80, 0x01, Handler Full
0x80, 0x03, Source Magazine not installed
0x80, 0x04, Medium destination element not installed
0x80, 0x05, Source Drive not installed
0x80, 0x06, Destination Drive not installed
0x80, 0x07, I/O Port access or Import prohibited by configuration
0x83, 0x00, Label information is questionable
0x83, 0x01, Label scan error
0x83, 0x02, Magazine not present
0x83, 0x03, Full and label information questionable
0x83, 0x04, Drive not present
0x83, 0x07, Full information questionable.
0x83, 0x09, No label information
0x83, 0x10, Element is in error
0x85, 0x01, No Barcode Reader installed
0x90, 0x02, Magazine not present
0x90, 0x03, Full information questionable