# NetWorker
# 7.2.2.Build.422
# LEGATO Software, a division of EMC.
#
# EXABYTE ASC/ASCQ Error Codes
#
0x04, 0x83, The front door is open
0x04, 0x89, The library is in console mode
0x04, 0x8d, The library is in lcd mode
0x04, 0x8e, The library is in sequential mode
0x15, 0x80, robot dropped a cartridge
0x15, 0x81, robot pick failure
0x15, 0x83, robot put failure
0x15, 0x86, robot get failure
0x28, 0x89, in scsi mode, after console mode
0x28, 0x8d, in scsi mode, after lcd mode
0x28, 0x8e, in scsi mode, after seq mode
0x3b, 0x81, firmware error
0x3b, 0x83, cartridge inaccessible
0x3b, 0x87, drive did not eject
0x3b, 0x90, drive inside source, not accessible
0x3b, 0x91, move interrupted
0x3f, 0x80, unable to erase EEPROM
0x3f, 0x84, unable to program EEPROM
0x3f, 0x86, eeprom checksum error
0x3f, 0x87, can not execute fw command,  wt inprog
0x3f, 0x88, can not execute fw command, rd inprog
0x3f, 0x8b, EEPROM header invalid
0x40, 0x88, front door open
0x40, 0x8b, m bus failed
0x40, 0x8c, m bus interrupt timeout
0x40, 0x8d, m bus ack failure
0x40, 0x8f, robot gripper error
0x40, 0x91, gripper home error
0x40, 0xa0, r axis does not move
0x40, 0xa1, r axis does failed home
0x40, 0xa3, r reset failed
0x40, 0xa6, rrc sensor failure
0x40, 0xa8, rrc communication failure
0x40, 0xad, h axis does not move
0x40, 0xae, h axis has failed home
0x40, 0xaf, h reset failed
0x40, 0xb0, v axis does not move
0x40, 0xb1, v axis has failed home
0x40, 0xb3, v reset failed
0x40, 0xc0, w axis does not move
0x40, 0xc1, w axis has failed home
0x40, 0xc2, w front sensor failed
0x40, 0xc3, w reset failed
0x40, 0xc5, w axis interference
0x40, 0xc6, mult drum indices
0x40, 0xd1, ee port failed to extend/unlock
0x40, 0xd2, ee port failed to return/lock
0x40, 0xd7, ee port door open
0x40, 0xe0, did not read barcode
0x40, 0xe5, robot movement error
0x40, 0xf3, laser not calibrated
0x40, 0xf4, missing calibration target
0x53, 0x80, ee cartridge jammed
0x5d, 0xff, tape alert asyn notification test
0x80, 0x01, robot full before move
0x80, 0x02, cannot execute - ee port is extended/unlocked
0x80, 0x03, no source element
0x80, 0x04, no destination element
0x80, 0x05, source drive not installed
0x80, 0x06, destination drive not installed
0x80, 0x0d, calibrate drive occupied
0x80, 0x0e, drive removed
0x80, 0x0f, drive added
0x83, 0x01, bar code label is questionable
0x83, 0x02, cannot read bar code label
0x83, 0x03, no magazine is installed at slot
0x83, 0x08, bar code label is upside down
0x83, 0x09, no bar code label - bar codes required
0x83, 0x10, x axis calibration failed
0x84, 0x00, internal sw error
0x84, 0x05, rrc command reject
0x84, 0x10, library os failure
0x84, 0x11, library could not set alarm
0x84, 0x12, library os message failure
0x84, 0x20, drive hw error
0x84, 0x21, drive not talking
0x85, 0x01, no bar code scanner
0x85, 0x02, cannot scan label - in drive
0x85, 0x03, invalid x card configuration
0x85, 0x10, bad calibration value
0x85, 0x11, robot fru data bad
0x87, 0x21, drive comm failed
0x87, 0x23, drive comm timeout
0x87, 0x24, drive load command failed
0x87, 0x25, drive not ready
0x87, 0x26, drive command failure