| Diagnostic | Description | 
|---|
| a3500fctest(1M) | In-band diagnostic for Sun StorEdge A3500FC LUNs attached via the host data-path. 
 | 
| a5ksestest(1M) | In-band diagnostic for Sun StorEdge A5000 Enclosures attached via the host data-path. | 
| a5ktest(1M) | In-band diagnostic for Sun StorEdge A5000 disk drives attached via the host data-path. | 
| brocadetest(1M) | Out-of-band diagnostic for testing ports on Brocade Silkworm Fibre Channel switch. | 
| d2disktest(1M) | SCSI disk diagnostic for Sun StorEdge D2 SCSI disks. | 
| daksestest(1M) | In-band diagnostic for Sun Fire V880 Enclosures attached via the host data-path. | 
| daktest(1M) | In-band diagnostic for Sun Fire V880 disk drives attached via the host data-path. | 
| fcdisktest(1M) | In-band diagnostic for Internal FC disk drives attached via the host data-path. | 
| fctapetest(1M) | In-band diagnostic for FC Tape drives attached via the host data-path. | 
| ifptest(1M) | Sun StorEdge PCI FC-100 Host Bus Adapter diagnostic for HBAs using the ifp driver | 
| qlctest(1M) | Sun StorEdge PCI Dual Fibre Channel Host Bus Adapter diagnostic for HBAs using the qlc driver. | 
| socaltest(1M) | Sun StorEdge SBus FC-100 Host Bus Adapter diagnostic for HBAs using the socal driver. | 
| linktest(1M) | The linktest is designed to test two end points of a FC link segment
and assist the user in FRU isolation of the link segment. This test is typically run when the FCAL topology indicates a link problem. i.e. A red link. | 
| switchtest(1M) | Out-of-band diagnostic for testing ports on Sun StorEdge Network FC switch-8 and switch-16. | 
| switch2test(1M) | Out-of-band diagnostic for testing ports on Sun StorEdge Network FC 2 Gigabit switch-8 and switch-16. | 
| t3test(1M) | In-band diagnostic for Sun StorEdge T3 and T3+ LUNs attached via the host data-path. | 
| t3volverify(1M) | Out-of-band diagnostic for Sun StorEdge T3 and T3+ LUNs attached via the ethernet connection. t3volverify will execute the volume verify function on the selected T3. | 
| se_configcheck(1M) | Verify the configuration of a Sun Solution System (3900/6900). | 
| se2_configcheck(1M) | Verify the configuration of a Sun Solution System (6320). | 
| vediag(1M) | Out-of-band diagnostic for Virtualization Engine (VE) attached via the ethernet connection. Initiates and monitors diagnostics on the virtualization engine. | 
| veluntest(1M) | In-band diagnostic for Virtualization Engine VE attached storage. Verifies the functionality of the in-band virtualization engine Sun StorEdge 3900/6900 Series LUN(s). | 
| Exercisors | stresstest(1M) | In-band exercisor for all I/O devices attached via a host data-path. |  | dex(1M) | In-band exercisor for all disk and tape drives attached via the host data-path. |  | lbf(1M) | In-band exercisor for FC loops(media) utilized by the host Sun StorEdge HBAs soc+ and QLC 2200. |  |