Modeling Language

John Harrold & Anson Abraham

2020-07-05

Introduction

At its core, ubiquity is a modeling language and a set of scripts meant to facilitate model development and deployment. The focus of this document is on the model description language. This is a plain text file, referred to as a system file. Each line contains a descriptor (e.g. <P>) which defines an aspect of the model, and comments are made with the hash sign (#). What follows is an overview of the different components of the language that can be used to create a system file.

Parameters

System parameters <P>

Each system parameter is specified with a name, value, lower bound, upper bound, units, whether it should be editable in the ShinyApp and the ‘type’ of parameter (grouping in the ShinyApp). The values of eps (machine precision, smallest value that is not zero) and inf (infinity) can be used. For example to specify a parameter koffR with a value of .1 that is positive and a parameter KDR with a value of .04 that is also positive:

#   name  value    lb     ub   units  editable type
<P> koffR 0.1      eps    inf   1/hr  yes      Target
<P> KDR   0.04     eps    inf   nM    yes      Target

Parameter sets

Often a model will be developed to incorporate different situations or scenarios. For example, a model may be used to describe both healthy and diseased individuals. When these differences are simply parametric in nature, it can be cumbersome to code a model multiple times (once for each parameterization). This framework provides a mechanism for including multiple parameterizations withing the same system file. Consider the system below where we want to describe antibody disposition. For humans this is described by a two compartment model, but for mice a single compartment is needed.

Model parameterizations

Model parameterizations

First we create a set of parameters describing the human scenario. These are the mean parameters taken from the literature [DM]:

<P> Weight   70.0    eps inf kg   yes   System # Organism weight
<P> CL        0.0129 eps inf L/hr yes   System # Systemic Clearance
<P> Q         0.0329 eps inf L/hr yes   System # Inter-compartmental clearance
<P> Vp        3.1    eps inf L    yes   System # Vol. central compartment
<P> Vt        2.8    eps inf L    yes   System # Vol. peripheral compartment

When a parameter is created using the <P> descriptor it is part of the default parameter set. This is the short name1 for a parameter set. A longer more verbose name can be given as well, and this is what will be seen in the ShinyApp. The human parameter set can be labeled using the PSET descriptor in the following way:

<PSET:default> mAb in Human

Where default is the parameter set short name name, and “mAb in Human” is the value shown to the user in the ShinyApp.

Next, to add the parameterization for mice we simply create a new set in the following way:

<PSET:mouse> mAb in Mouse

This alone would create a new parameter set with a short name mouse, and is an exact copy of the default parameter set. To identify the parametric differences between the mouse and human we use PSET in the following way:

<PSET:mouse:Weight > 0.020 # 20 gram mouse
<PSET:mouse:CL >     7.71e-6
<PSET:mouse:Q>       0.0
<PSET:mouse:Vp >     1.6e-3
<PSET:mouse:Vt >     1   # arbitrary

Consider the clearance parameter entry where we want the murine half-life of an antibody [VR]:

<PSET:mouse:CL> 7.71e-6

We use the set name (mouse) and the parameter name (CL) and then we overwrite the default with the specified value 7.71e-6. The other aspects of the parameter (bounds, edit flag, etc.) will be the same as the default value.

Secondary parameters <As> and <Ad>

A static secondary parameter refers to parameter does not change during a simulation. These are specified using the <As> descriptor and can be written in terms of system parameters or previously defined static secondary parameters. These can be used in differential equations, defining initial conditions, input scaling and model outputs. This is similar to secondary parameters defined in the $PK block in NONMEM. For example, if you wanted to define the rate of elimination in terms of the system parameters for clearance CL and volume of distribution Vp the following would be used:

<As> kel = CL/Vp

A dynamic secondary parameters refers to a parameter that can change during a simulation. This typically means it is defined, using the <Ad> descriptor, in terms of a state or another dynamic secondary parameter. These can be used in differential equations and model outputs. These are similar to the parameters defined in the $DES block in NONMEM. For example if you wanted to use the concentration in the central compartment Cp but it was dependent on the amount in that compartment Ap and the volume of that compartment Vp the following would be used:

<Ad> Cp = Ap/Vp

Variance parameters <VP>

Variance parameters are specified using the same format as system parameters (<P>) :

#    name    value lower_bound upper_bound units editable grouping
<VP > SLOPE  0.01  eps         inf         1/hr   yes     Variance

The difference being that the <VP> descriptor is used and that the grouping is set to Variance. These are used when performing parameter estimation and when simulating with residual variability.

Variability: defining the variance/covariance Matrix <IIV:?>? & <IIVCOR:?>?

Any variable name assigned to inter-individual variability (IIV) or correlation/covariance (IIVCOR) term that makes sense to the user may be used. The following sample codes have variable names (eg: ETACL) that most likely make sense to a population modeler or NONMEM user. To define an IIV term named ETACL with a variance of 0.15 use the following:

<IIV:ETACL> 0.15

The next we need to associate this IIV term with a system parameter. To associate this IIV term with the clearance (system parameter CL) and specify that it has a log normal distribution (LN) we would simply write:

<IIV:ETACL:LN> CL

Alternatively a normal (N) distribution can be used.

Next we specify the IIV term ETAV with a variance of 0.1. This IIV term also has a log normal distribution and is applied to the parameter V:

<IIV:ETAV> 0.10
<IIV:ETAV:LN> V

Now we can define the covariance (off-diagonal elements) between CL and V to be 0.01 by using:

<IIVCOR:ETAV:ETACL> 0.01

The order isn’t important and the IIV terms can be reversed

IIV and parameter sets <IIVSET:?>? & <IIVCORSET:?>?

By default all parameter sets will have inter individual variability specified using the <IIV> and <IIVCOR> descriptors. To associate a specific set of IIVs to a parameter set use the <IIVSET> and <IIVCORSET> descriptors. These set descriptors operate differently than the parameter set descriptors (<PSET>). The <PSET> just overwrites the default values and inherits the default variance/covariance information. If you alter the IIV information for a parameter set it will reset the IIV information for that parameter set. The entire variance covariance matrix will need to be specified for that parameter set.

If the parameter set MYPSET has been defined then the following could be used to define the IIV for the parameters Q and CL:

<IIVSET:MYPSET:ETAQ>           0.05
<IIVSET:MYPSET:ETAQ:LN>        Q

<IIVSET:MYPSET:ETACL>          0.25
<IIVSET:MYPSET:ETACL:LN>       CL

<IIVCORSET:MYPSET:ETAQ:ETACL>  0.01

All the other system parameters will have no IIV information for this parameter set.

Differential equations

The differential equations in the system can be defined by simply writing them out. Alternative they can ‘built’ by using the different descriptors provided below. Part of the flexibility of ubiquity lies in the ability to combine these different notations. To construct a model (see section below: Bringing it all together) any combination of the five following methods can be used:

  1. Differential equations <ODE:?>
  2. Reaction rates =?=>
  3. Equilibrium relationships <=kforward:kreverse=>
  4. Sources and sinks <S:?>
  5. Movement between compartments <C>

Writing ODEs <ODE:?>

Portions of differential equations can be specified here where ? is the state or compartment. To define dA/dT as koffR*C - konR*A*B we would write:

<ODE:A> koffR*C - konR*A*B 

It might be more convenient to specify an ODE across several lines, making things more readable. Just use multiple statements and they will be appended together. This would give the same result as the example above:

<ODE:A>    koffR*C
<ODE:A>  - konR*A*B 

Rate equations =?=>

It may be more convenient to write out chemical reactions rather than differential equations. This can be done using the general form:

[CR1]Reactant1 + [CR2]Reactant2 + ... =kf=> [CP1]Product1 + [CP2]Product2 + ...

Where the stoichiometric coefficients, beginning with CR and CP above, in brackets only need to be specified if they are not one. The reaction order will be assumed to be equal to the stoichiometric coefficient of the reactant. For a more specific example Consider decomposition of hydrogen peroxide into water and oxygen:

\[ H_2O_2 \xrightarrow{k_{deg}} H_2O + \frac{1}{2}O_2 \]

In the system format this would be written in the following manner:

H2O2 =kdeg=> H2O + [0.5]O2

And this will be translated in to the following differential equations:

<ODE:H2O2>   - kdeg*H2O2 
<ODE:H2O>      kdeg*H2O2 
<ODE:O2>   0.5*kdeg*H2O2 

The rates (e.g. kdeg) need to be defined as either a system or secondary parameter. This is where you can put saturable terms, such as Michaelis-Menten kinetics.

Equilibrium relationships <=kforward:kreverse=>

Forward and reverse reaction rates can be written separately:

A + B =konR=>   C       
C     =koffR=>  A + B

Or these can be written as equilibrium equations:

A + B  <=konR:koffR=>  C       

To write this as differential equations, the following would be used:

<ODE:A>  koffR*C - konR*A*B
<ODE:B>  koffR*C - konR*A*B
<ODE:C> -koffR*C + konR*A*B

Sources and sinks <S:?>

This method allows turnover to be described in terms of synthesis and degradation terms. If A is produced at a rate of ksynA (mass quantities), degraded at a rate of kdegA, and modeled in concentration units then the sources are specified on the left hand side of <S:?> and the sinks (elimination) are specified on the left hand side of <S:?>. Multiple sources and sinks can be separated by semicolons. In this example with a compartment volume V

ksynA/V <S:A> kdeg*A

Which is the same as writing out the differential equation:

<ODE:A> koffR*C - konR*A*B + ksynA/V - kdeg*A

Movement between compartments <C>

When mass moves between two physical spaces with different volumes we need to specify, for each compartment, the species, volume and rate of transport. The <C> descriptor allows us to just identify the compartment information separated by semicolons (order is important)

Species; Volume; Rate <C> Species; Volume; Rate

For movement between a central compartment A with a volume V to the tissue space At with a volume Vt at rates kps and ksp respectively this is specified in the following manner:

A; V; kps <C> At; Vt; ksp

Which is the equivalent of the following differential equation:

<ODE:A>   -kps*A + ksp*At*Vt/V
<ODE:At>  +kps*A*V/Vt - ksp*At

Bringing it all together

ODEs vs. Model Descriptors

ODEs vs. Model Descriptors

As a final example consider the target-mediated drug disposition system above. This system can be defined with a set of ODES:

<ODE:Ct>  Cp*kpt*Vp/Vt - Ct*ktp
<ODE:Cp> -Cp*kpt       + Ct*ktp*Vt/Vp -  kel*Cp   + koff*CpTp - kon*Cp*Tp
<ODE:Tp>               + ksyn/Vp      - kint*Tp   + koff*CpTp - kon*Cp*Tp
<ODE:CpTp>                            - kint*CpTp - koff*CpTp + kon*Cp*Tp

Or it could simply be defined in terms of the underlying processes:

# tissue distribution
Ct; Vt; ktp <C> Cp; Vp; kpt

# equilibrium
Cp + Tp <=kon:koff=> CpTp

# Turnover
 ksyn/Vp <S:Tp>   kint*Tp
         <S:Cp>    kel*Cp
         <S:CpTp> kint*CpTp

Initial conditions <I>

By default all initial conditions are zero. You can specify a non-zero initial condition using the <I> string to set a ‘state’ to a ‘value’

<I> state = value

Value can be any combination of numbers, system parameters <P> or static secondary parameters <As. Consider a turnover system where the value of ksyn and kdeg are specified as parameters:

<P> ksyn  0.1      eps    inf   1/hr  yes      Target
<P> kdeg  0.04     eps    inf   nM    yes      Target

We can calculate the initial value for a target as:

<As> T_IC = ksyn/kdeg

Then we can specify the initial value of the target as:

<I> T = T_IC

Model inputs

Inputs into the model include typical interventions such as bolus dosing or continuous infusions. However inputs here refers to mathematical inputs. Typically covariates may be attributes of the system (such as gender, or a specific genotype), but are treated here as inputs. When defining inputs it is necessary to provide typical/placeholder values. These provide default values for both the ShinyApp interface as well as the scripting level (Matlab and R) where they can be overwritten by the user.

Bolus dosing <B:times>, <B:events>

The <B:?> descriptor is used to define bolus dosing. Dosing information is broken down into a list of times when bolus injections occur and a list of events containing the amount the specified compartment will receive.

Each of these has a scale that is used to convert the bolus dosing information from proscribed units (mg daily) into the units in which the system is coded (nM and hours). So if dosing is done on days 0, 1, 2… but the simulation time is hours, then the scale for the dosing times is 24.

The events contain the magnitude of the bolus at a given time. If you have multiple compartments receiving a bolus, the times must include all times in which a bolus may be applied to the system. If a state does not receive a bolus on a particular time, it’s magnitude at that time is 0.

To illustrate this consider the following dosing schedule:

Dosing into two different states/compartments

Dosing into two different states/compartments

In this example we want to dose two different drugs into two different states/compartments. Drug 1 (D1) will be dosed into Cp1 and drug 2 (D2) into Cp2. Dosing will be in mg/kg but concentrations are in mg/ml. The dosing time is in days, but the simulation time units are hours. We will be dosing D1 at 8 & 2 mpk on days 0 & 6. D2 will be dosed at 5 mpk on day 9.

#  type       state     values     scale  units   
<B:times>;            [0 6 9];       24;  days   
<B:events>;    Cp1;   [8 2 0];    70/V1;  mpk   
<B:events>;    Cp2;   [0 0 5];    70/V2;  mpk   

Assume V1 and V2 are the compartmental volumes for D1 and D2 in ml, and the subject body weight is 70 kg. This would convert those doses in mpk into mg/ml. Again these are the default doses that can be overwritten both in the ShinyApp and within scripts.

Continuous infusions <R:?>

Rates of infusion are defined using the <R:?> descriptor. Like bolus values, infusion rates have two components. There is a component that specifies switching times (e.g. switching from 10 mg/hr to 0). And each switching time has a corresponding rate of infusion. This infusion rate will be held constant until the next time. Also like the bolus specification there is a scale associated with both infusion times and the levels that converts the proscriptive units into the units of the simulation. Consider the following example:

# name      time/levels values    scale  units
<R:myrate>; times;      [0 30];   1/60;    min
<R:myrate>; levels;     [1 0];    60;   mg/min

These two entries create the infusion rate called myrate. This can be used in any of your system specifications (e.g., <ODE:Cp> myrate/Vp). The first row specifies the times when the rate is changed (0 and 30 minutes). If the system is coded in terms of hours, then the scale of 1/60 must be used. The levels indicate a rate of 1 mg/min that is switched off at 30 minutes. This has to be converted to mg/hr using the scale of 60. You can add as many paired rate entries as you need to describe as many infusion interventions as necessary.

Covariates <CV:?>, <CVSET:?:?>

Simple covariates

For simulation purposes covariates (normally found in a dataset) need to be defined. Covariates can be either constant or change with time. The times values must be the same scale as the system. The following defines the value for the covariate RACE:

<CV:RACE>; times;  [0];     hours
<CV:RACE>; values; [1];     ethnicity

Covariates can also change with time. In this case consider the subject weight (WGT). It begins at 70 and measurements are made at several time points.

<CV:WGT>; times;  [ 0 1680 3360 5040 10080];     hours 
<CV:WGT>; values; [70   65   60   58    56];     kg     

Next we can alter how the simulations will interpret these values by setting the type of covariate. By default the weight will be linearly interpolated (type = linear), however we can hold the weight constant until the next measurement is encountered (last value carried forward) by declaring the type as step

<CVTYPE:WGT> step

Now if the model was parameterized for male and female subjects we can define two parameter sets (as described above) to account for this:

<PSET:default>  Male   
<PSET:female>   Female          

And the values for the covariate can be changed for the set ‘female’:

<CVSET:female:WGT>; times;   [ 0 1680 3360 10080]
<CVSET:female:WGT>; values;  [60   55   52    50]

Complicated covariates

Detailed time course profiles can be created as well. For example, to create a covariate profile that is zero from time 0-1 and at time 1 it jumps to 8 and decreases at a rate of 1 per unit time until time 5 where it stays at the value 4 until time 12. It might have a profile like the following:

Time-varying covariate input profile

Time-varying covariate input profile

# name        time/values  values                         units
<CV:mycov>  ; times;       [0 .999 1 5 12];  hours
<CV:mycov>  ; values;      [0 0    8 4 4 ];  --   
<CVTYPE:mycov> linear

Model outputs

Outputs are defined here in terms of states, parameters, secondary parameters, input rates, and covariates listed above. The format used is:

<O> name = expression

For example:

<O> A_obs = A
<O> Coverage = A/(KD + A)
<O> QC_CLtot = Cp*CL/Vp + Cp*Vmax/(Km+Cp)

Outputs that begin with QC, like QC_CLtot above, will not be displayed in the ShinyApp. This is intended to make them available at the scripting level for quality control (QC) purposes.

Functions and operators

Most of the standard operators behave as expected (+, -, *, & /) because most languages use these consistently. There are however certain operators and functions that differ between languages. For example, consider the power function (\(a^b\)). In FORTRAN this would be a**b, in Matlab it is a^b, and in C it is pow(a,b). Given the objectives here (write once and create multiple formats), this can be quite challenging. The solution used here is to convert language specific functions and operators into generic functions. So the power operator would be:

SIMINT_POWER[a][b]

This would then be converted to the appropriate output format depending on the output target. The following generic functions can be used:

Operator/Function Example Format
power \(a^b\) SIMINT_POWER[a][b]
exponential \(e^a\) SIMINT_EXP[a]
log base 10 \(\log(a)\) SIMINT_LOG10[a]
log base e \(\ln(a)\) SIMINT_LOGN[a]
less than \(a < b\) SIMINT_LT[a][b]
less than or equal \(a \le b\) SIMINT_LE[a][b]
greater than \(a > b\) SIMINT_GT[a][b]
greater than or equal \(a \ge b\) SIMINT_GE[a][b]
equal \(a == b\) SIMINT_EQ[a][b]
and \(a \& b\) SIMINT_AND[a][b]

Current simulation time

For some systems you will want to access the simulation time. To do this you can use the internal variable SIMINT_TIME.

Modeling quasi-equilibrium of target-mediated drugs

The free amount of a drug Cfree which is binding to a receptor with an affinity of KD given total values Ctot and Rtot the following can be calculated using the following equation:

\[ C_{free}=\frac{1}{2} \left[ (C_{tot}-R_{tot}-K_D) + \sqrt{(C_{tot}-R_{tot}-K_D)^2 + 4K_DC_{tot}} \right] \]

This can be tedious, especially using the generic functions above. To make this easier you can use the following generic function:

<Ad> Cfree = SIMINT_QEQ[Ctot][Rtot][KD]

To get Rfree, just switch the first two arguments:

<Ad> Rfree = SIMINT_QEQ[Rtot][Ctot][KD]

Timescales

Each system has default units in which it is constructed, and should be indicated in the comments of the model. It can be useful (for generating figures for example) to show simulations in different time scales. Now this can be achieved by multiplying the time outputs by the correct scaling factor. However this requires the end user to (1) remember the original timescale and (2) correctly scale that value.

Now while this is not particularly challenging from a mathematical perspective, it introduces a chance for error. It is possible, instead, to specify time scale information using the <TS:?> descriptor. If the system is coded in hours, the following will define timescales for the default (hours), days, weeks and months:

<TS:hours>  1.0
<TS:days>   1.0/24.0
<TS:weeks>  1.0/24.0/7.0
<TS:months> 1.0/24.0/7.0/4.0

These are used both in the ShinyApp and at the command line in Matlab and R

Mathematical sets

Consider the following systems:

PBPK: Most of the organs in these systems are mathematically identical, with only variations in the parameters. However coding each of these organs or modifying an existing system (say to incorporate the presences of a target in each organ) can become tedious.

Anti-drug antibody generation: If we consider ADAs generated in response to therapeutic proteins, the response will consist of a distribution of ADAs in terms of their concentration and a separate distribution in terms of their affinity. Modeling this maturation process and the interactions between the ADAs, the therapeutic protein, and drug targets becomes unmanageable quickly.

The question is: How can we make difficult problems easy and intractable problems possible? The solution implemented here allows the system to be defined in terms of mathematical sets

Set notation <SET:?>?

Consider the interactions occurring in an assay designed to detect drug (D) present in serum. In this assay a biotinylated target (TB) is used to pull down the drug and a labeled target (TL) is the signaling molecule used. The assay will provide a signal when a complex containing both TB and TL are present (TB:D:TL or TL:D:TB). Samples can contain soluble target as well (TS) which can interfere with the assay. To model this assay, the following interactions should be considered:

Mathematical sets

Mathematical sets

Several options are available to construct this system. The ODEs could simply be typed out for every possible combination. It’s also possible to use the equilibrium <=kon:koff=> for all the interactions as well. However, there is another option that will handle the enumeration more easily. First we define the two mathematical sets TSi and TSk:

<SET:TSi> TL; TB; TS
<SET:TSk> TL; TB; TS

With these defined we can then use the curly brace notation ({ }) with any of the descriptors used to construct a system. For example, the initial conditions for each of the target states are defined as parameters (T0_TL, T0_TS, T0_TB) in the model. These have to be identified as initial conditions using the <I> notation, and can be done with a single statement. This line:

<I> {TSi} = T0_{TSi} 

Expands to:

<I> TL = T0_TL
<I> TB = T0_TB
<I> TS = T0_TS

Similar to the initial condition, the equilibrium between the monomeric drug and the different targets can be defined using a single statement:

D + {TSi} <=kon:koff=> D_{TSi}

That uses only one of the sets (TSi) and will be expanded for each element in that set. To account for the formation of complexes that contain a drug molecule and two different target molecules, the following statement is used:

D_{TSi} + {TSk} <=kon:koff=> {TSk}_D_{TSi}

This statement contains two different sets (TSi and TSk). When multiple sets are encountered, every possible combination is evaluated

Aligning Sets

By default sets will interpreted by evaulating every possible permutation as shown above. However, it may be desireable to pair or align sets. Take for example the transit compartments implemented by Lobo and Balthasar to delay the onset of drug effect on cancer cells [LB]. The traisnt compartment are implemented using a series of differential equations:

\[ \frac{dK1}{dt} = (K-K1)\frac{1}{\tau} \\ \frac{dK2}{dt} = (K1-K2)\frac{1}{\tau} \\ \frac{dK3}{dt} = (K2-K3)\frac{1}{\tau} \\ \frac{dK4}{dt} = (K3-K4)\frac{1}{\tau} \]

It’s possible to code each of these individually, but it’s also possible to define these using mathematical set notation. We see that in the first equation K is paired or aligned with K1, and in the second it’s K1 and K2, etc. So first we define two sets of equal length whose elements are aligned:

<SET:TRIN>    K; K1; K2; K3
<SET:TROUT>  K1; K2; K3; K4 

Next we write the <ODE:?>? statment in terms of these sets, but we use the SIMINT_SET_ALIGN function:

SIMINT_SET_ALIGN[TRIN;TROUT][<ODE:{TROUT}> 1.0/tau*({TRIN}-{TROUT})]

The first argument is the names of sets to align separated by a simicolon ; and the second argment is the system file descriptor written in terms of these sets. This will be expanded internally into:

<ODE:K1> 1.0/tau*(K-K1)
<ODE:K2> 1.0/tau*(K1-K2)
<ODE:K3> 1.0/tau*(K2-K3)
<ODE:K4> 1.0/tau*(K3-K4)

Set Functions

It can be useful to perform operations over sets. To do this you can use the following functions:

  • SIMINT_SET_SUM is the mathematical equivalent of \(\sum_{SET}\)
  • SIMINT_SET_PRODUCT is the mathematical equivalent of \(\prod_{SET}\)

These functions take two bracketed arguments. The first argument is the set name and the second argument is the mathematical relationship to be expanded. For example, consider a system that has been parameterized for several species. The variable EN_Mouse is 1 if the species is mouse and 0 otherwise. Similarly for EN_Human, EN_Monkey, etc. We have also defined the body weights as system parameters: BW_Mouse for the mouse, BW_Human for human, etc. Now we want to assign BW to the value of the currently seleted species (where EN for that species is 1). First we would define the species parameter set:

<SET:SP> Mouse; Rat; Monkey; Human

Next we would define the secondary parameter BW by summing the product of the Boolean species parameter and the body weight for that species:

<As> BW = SIMINT_SET_SUM[SP][EN_{SP}*BW_{SP}]

Set Evaluation

Sets are evaulated in the following order:

  • First set functions (SIMINT_SET_SUM and SIMINT_SET_PRODUCT) are evaulated.
  • Next aligned sets are applied (SIMINT_SET_ALIGN)
  • Lastly, remaining sets are evaulated for every permutation

Piecewise-continuous functions/parameters <IF:?:?>

To specify a conditional assignment use the statement:

<IF:name:COND> boolean; value

Here name is the name of the secondary parameter be defined and COND indicates that we have a Boolean condition that needs to be satisfied. The condition (boolean) can be and, or, greater than, etc. relationships. The parameter will be assigned to have the value when this Boolean relationship is true. These conditions can be a function of different elements of the system depending on whether or not name refers to a static or dynamic secondary parameter:

It is important to include a default ELSE condition:

<IF:name:ELSE> value

Constructing a piece-wise continuous function/parameter

To see an example use the following command (use ?system_new to see a list of the available system file examples):

system_new(system_file="pwc", file_name="system-pwc.txt")

In this example we specify fast (kelf) and slow (kels) rates of elimination. We want to have the fast rate be active when the drug concentration is above Cth and the time is below Tf. The system parameters would look like:

<P> kelf   1.0  eps inf   1/time   yes System
<P> kels   0.01 eps inf   1/time   yes System
<P> Cth   10    eps inf   conc     yes System
<P> Tf    10    eps inf   time     yes System

Now we need to define the rate of elimination such that the constraints above are followed. First we define kel as a dynamic secondary parameter with a value of 0.0. Then we define the different conditions and relevant values:

<Ad > kel = 0.0
<IF:kel:COND> SIMINT_AND[SIMINT_LT[SIMINT_TIME][Tf]][ SIMINT_GT[Cp][Cth]]; kelf
<IF:kel:ELSE> kels

Controlling indices

By default, the build script will construct odes, parameter sets, etc. automatically. This means that the order of states/compartments are going to be arbitrary. Sometimes it is necessary to specify the order of your states or outputs. For example when using NONMEM the order in the control stream must correlate with the values in the dataset. To specify that a state Cp should be compartment 3, the following should be used:

<INDEX:STATE:Cp>  3

The general notation for an output or state name assigned to a number is:

<INDEX:STATE:name>  number
<INDEX:OUTPUT:name> number

Options

Several options can be specified using the <OPT:? delimiter. If you’ve defined the days timescale using <TS:?>? this can be used as the timescale for plotting in the ShinyApp by using:

<OPT:TS>  days

To define the default output times for the ShinyApp and simulation scripts use the following:

<OPT:output_times> SIMINT_SEQ[0][100][1]

Example system files

These example system files can be found in the examples directory of the stand-alone analysis template (ubiquity_template.zip). Most can also be loaded form the R package (see the help for system_new).

References


  1. parameter set short names must start with a letter and containing only letters, numbers, and _